건물에너지효율등급 적용에 따른 초단열 슈퍼윈도우 열성능 평가연구논문 2018. 10. 10. 10:51반응형
건물에너지효율등급 적용에 따른 초단열 슈퍼윈도우 열성능 평가
A study on the Insulation Performance of the SuperWindow considering the Evaluation of Building Energy Rating저자 장철용, 김치훈, 안병립, 홍원화
소속 한국에너지기술연구원, 경북대학교 건축공학과, 경북대학교학술지정보 한국태양에너지학회논문집 KCI
발행정보 한국태양에너지학회 2010년
자료제공처 국회도서관 KISTI 기계·건설공학연구정보센터 건축도시연구정보센터 한국연구재단
주제분야 공학 > 기타공학건물에너지효율등급 적용에 따른 초단열 슈퍼윈도우 열성능 평가.pdf
<초록>
Generally, the building's windows and ventilation for the purpose of mining and the vista and windows by emotional engineering design area is a growing trend. In addition, the building regulation U-value limitation of window is 3.3W/㎡․K in southern regions, while U-value limitation of wall is 0.35~0.58W/㎡․K. It means that the energy loss through windows is six times more than it through wall. Therefore, the purpose of this study is to evaluate the environmental performance of the super window system by verification experiment . The results of this study are as follows; 1) The insulation performance of super window system is 1.44 W/㎡℃ 2)Super Window compared to a normal window reduce heating energy requirements have been 5.3% 3)Compared to a normal window, Super window savings rate was 4.1% lower 4)Building energy efficiency rating was up to 1 rating from 2 rating.
Generally, the building's windows and ventilation for the purpose of mining and the vista and windows by emotional engineering design area is a growing trend.In addition, the building regulation U-value limitation of window is $3.3W/m^2{\cdot}K$ in southern regions, while U-value limitation of wall is $0.35{\sim}0.58W/m^2{\cdot}K$. It means that the energy loss through windows is six times more than it through wall. Therefore, the purpose of this study is to evaluate the environmental performance of the super window system by verification experiment. The results of this study are as follows; 1) The insulation performance of super window system is $1.44\;W/m^2^{\circ}C$ 2) Super Window compared to a normal window reduce heating energy requirements have been 5.3% 3) Compared to a normal window, Super window savings rate was 4.1% lower 4) Building energy efficiency rating was up to 1 rating from 2 rating.녹색건축인증 조성법' 및 '건물에너지 소비증명제'가 의무화되어 시행되고 있습니다. 저희 (주)녹색건축인증연구소는 '지속가능한 저탄소 녹색건축인증 기술연구소'의 전문기업으로 설립되어, 빠른 제도 변화와 변모하는 건설환경에 이바지하고자 합니다. (주)녹색건축인증연구소는 건축, 도시, 생태분야가 녹색건축물에 접목될 수 있도록 적절한 요소분석을 통해 에너지 절감형 건축, 자생적 생태환경, 온열환경, 빛환경의 면밀한 조사와 연구로 고객의 삶의 질 향상 및 더 나아가 인류의 존속성에 그 목적을 두고 있습니다
728x90반응형'연구논문' 카테고리의 다른 글
수질오염총량관리제의 합리적인 시행을 위한 시행절차 개선방안 (0) 2018.10.10 사무소건물 층수 증가에 따른 BIPV 발전량과 건물에너지소비량 저감에 관한 연구 (0) 2018.10.10 공동주택 층간소음 관련 제도개선 방향 (0) 2018.10.08 공동주택 층간소음 관련 제도개선 방향 (0) 2018.10.08 주택법 개정안의 파급 효과와 대안 (0) 2018.10.08