건물에너지 모니터링 및 시뮬레이션을 활용한 신축건물의 에너지성능평가연구논문 2018. 10. 23. 10:26반응형
건물에너지 모니터링 및 시뮬레이션을 활용한 신축건물의 에너지성능평가
Energy Performance Evaluation of a New Commercial Building using Calibrated As-built Simulation with Monitoring Data
저자 송수원
소속 연세대학교
학술지정보 설비공학논문집 KCI
발행정보 대한설비공학회 2008년
자료제공처 국회도서관 KISTI 국립중앙도서관 건축도시연구정보센터 한국연구재단
주제분야 공학 > 기타공학<초록>
The performance evaluation of a new building is becoming more important because efficient design alone is often not sufficient to deliver an efficient building. However, there is a lack of standard evaluation methods to measure the energy performance of a new construction that has Energy Conservation Design Measures (ECDMs). This study presents an enhanced method based on calibrated whole-building simulation for evaluating the energy performance of new commercial buildings and demonstrates its use using a case-study building, including: an Energy Use Index (EUI) comparison with sub-metered data and an evaluation of the performance of specific ECDMs. The use of this method has determined that the case-study building was shown to use approximately 47% less energy than the base-case building that has the same shape and function as the case-study building (i.e., calibrated as-built simulation model), but doesn't include the simulated ECDMs.The performance evaluation of a new building is becoming more important because efficient design alone is often not sufficient to deliver an efficient building. However, there is a lack of standard evaluation methods to measure the energy performance of a new construction that has Energy Conservation Design Measures(ECDMs). This study presents an enhanced method based on calibrated whole-building simulation for evaluating the energy performance of new commercial buildings and demonstrates its use using a case-study building, including: an Energy Use Index(EUI) comparison with sub-metered data and an evaluation of the performance of specific ECDMs. The use of this method has determined that the case-study building was shown to use approximately 47% less energy than the base-case building that has the same shape and function as the case-study building(i.e., calibrated as-built simulation mode]), but doesn't include the simulated ECDMs.
<목차>
ABSTRACT 1. 서론 2. 사례연구 대상건물 3. 시뮬레이션 모델 및 조건 4. 결과 및 고찰 5. 결론 후기 참고문헌녹색건축인증 조성법' 및 '건물에너지 소비증명제'가 의무화되어 시행되고 있습니다. 저희 (주)녹색건축인증연구소는 '지속가능한 저탄소 녹색건축인증 기술연구소'의 전문기업으로 설립되어, 빠른 제도 변화와 변모하는 건설환경에 이바지하고자 합니다. (주)녹색건축인증연구소는 건축, 도시, 생태분야가 녹색건축물에 접목될 수 있도록 적절한 요소분석을 통해 에너지 절감형 건축, 자생적 생태환경, 온열환경, 빛환경의 면밀한 조사와 연구로 고객의 삶의 질 향상 및 더 나아가 인류의 존속성에 그 목적을 두고 있습니다
728x90반응형'연구논문' 카테고리의 다른 글
일본의 에너지절약 건축기술의 인정제도에 대하여 (0) 2018.10.24 고층 건축물의 수평진동에 대한 사용자의 지각임계가속도 (0) 2018.10.23 거대억새를 이용한 대체 단열 건축내장재 및 식생블럭, 식생포트 제조기술개발 (0) 2018.10.23 환경소음 관련 주민반응에 대한 설문조사 방법 : 항공소음을 중심으로 (0) 2018.10.22 쉴드 TBM 터널 공사시 지반환경 영향성 검토 : 몽촌토성 지하철 공사 (0) 2018.10.22